ラジウム入りのセラミックボール
ttp://2ch-ita.net/upfiles/file16324.jpg identified nuclides
Th228, 1.72E04 +/- 2.6E03Bq, 2/3 peaks ( 40, 91)
Ra226, 6.05E03 +/- 2.E03Bq, 2/7 peaks ( 54, 91) uncertain 1),3)
Ba133, 2.41E03 +/- 1.1E03Bq, 1/1 peaks ( 54) very uncertain 1),3)
Pd103, 6.79E06 +/- 3.E06Bq, 1/2 peaks ( 54) very uncertain 1),3)
Ir194, 1.15E04 +/- 5.E03Bq, 1/3 peaks ( 54) very uncertain 1),3)
I 131, 1.84E03 +/- 8.1E02Bq, 1/2 peaks ( 54) very uncertain 1),2),3)
Th232, 1.64E04 +/- 2.5E03Bq, 2/7 peaks ( 40, 91) very uncertain 1),5)
Eu152, 5.64E03 +/- 2.5E03Bq, 1/7 peaks ( 54) very uncertain 1),3),5)
Bi207, 3.87E03 +/- 1.7E03Bq, 1/2 peaks ( 91) very uncertain 1),2),5)
1) Responsible peak is assigned to more than one nuclide.
Try longer measurement time to eventually find more peaks.
2) Responsible peak fits bad to library energy. Try to
recalibrate and repeat measurement.
3) Responsible peak has very low statistics. Try longer
measurement time to confirm.
5) Another significant peak is expected to be found. Try
longer measurement time to eventually find more peaks.
翻訳かけてみた
1)責任のピークは、複数の核種に割り当てられます。
最終的にはより多くのピークを見つけるために長い測定時間を試してみてください。
2)責任のピークは、ライブラリのエネルギーに悪い収まります。してみてください
再校正と測定を繰り返します。
3)責任のピークは非常に低い統計を持っています。長くしてみてください
確認のため測定時間。
5)もう一つの重要なピークが見られることが期待されている。試し
長い測定時間は、最終的にはより多くのピークを見つけるために。