>うちのファイル鯖機のHD753LJで、Offline data collection機能をonに設定してみた。
>smartctl -d ata --smart=on --offlineauto=on --saveauto=on /dev/sdX
ttp://pc11.2ch.net/test/read.cgi/jisaku/1217270978/627 経過報告 (崩れるだろうけどごめんよ)
># smartctl -d ata -s on -a /dev/sdX
=== START OF INFORMATION SECTION ===
Device Model: SAMSUNG HD753LJ
中略
Num Test_Description Status Remaining LifeTime(hours) LBA_of_first_error
# 1 Reserved offline Completed without error 00% 5275 -
# 2 Reserved offline Completed without error 00% 5215 -
# 3 Reserved offline Completed without error 00% 5155 -
# 4 Reserved offline Completed without error 00% 5095 -
# 5 Reserved offline Completed without error 00% 5035 -
# 6 Reserved offline Completed without error 00% 4975 -
# 7 Reserved offline Completed without error 00% 4915 -
# 8 Reserved offline Completed without error 00% 4855 -
# 9 Reserved offline Completed without error 00% 4795 -
以下略
だいたい50時間前後でselftest1回分を完了してるみたい。